Lieu d'origine: | Dongguan Chine |
Nom de marque: | B-TOP |
Numéro de modèle: | RJ45 magnétique Jack |
Quantité de commande min: | Négociable |
---|---|
Prix: | Negotiable |
Détails d'emballage: | Négociez |
Délai de livraison: | 10 jours de travail |
Conditions de paiement: | T/T |
Capacité d'approvisionnement: | 1000 PCS/Day |
Port: | 1*1 | LED: | Vert/vert |
---|---|---|---|
Plastique: | PBT | Étiquette d'IEM: | Oui |
Or-électrodéposition: | 6u » | vitesse: | gigabit |
Courant évalué: | 2A maximum | Application: | Carte PCB, audio, liaison de transmission de données |
Surligner: | POE Magnetic RJ45 Jack,Modular Magnetic RJ45 Jack,Angled Shielded rj45 modular jack |
Angled Shielded Type POE Magnetic 8P8C Modular Jack RJ45 Connector
Product Introduction
RJ45 is a type of connector commonly used for Ethernet networking. It looks similar to a telephone jack, but is slightly wider. Since Ethernet cables have an RJ45 connector on each end, Ethernet cables are sometimes also called RJ45 cables.
The "RJ" in RJ45 stands for "registered jack," since it is a standardized networking interface. The "45" simply refers to the number of the interface standard. Each RJ45 connector has eight pins, which means an RJ45 cable contains eight separate wires. If you look closely at the end of an
Ethernet cable, you can actually see the eight wires, which are each a different color. Four of them are solid colors, while the other four are striped.
Product features:
Body - Thermoplastic, UL94VO Black
Contacts - Phosphor Bronze
Contacts plated - Gold plated over Nickel, Solder Tails Tin plated over Nickel
Shield - Copper Alloy, Nickel Plated
Part Number | Size | Speed | Schematic | LED | EMI Spring | Gold Plating |
BT50S(27-11)F4-03A-P213-B52 | 21.35*15.9*13.5 | 100M | F4-03A | G/Y | No | 6u" |
B50S(27-12)F4-239-P123-B52 | 21.35*15.9*13.5 | 100M | F4-239 | Y/G | Yes | 6u" |
B50S(27-16)F4-117-P223-B52 | 21.35*15.9*13.5 | 100M | F4-117 | G/Y | Yes | 6u" |
B50S(27-19)F4-03A-P223-B52 | 21.35*15.9*13.5 | 100M | F4-03A | G/Y | Yes | 6u" |
B50S(27-22)F4-03A-P213-B52 | 21.35*15.9*13.5 | 100M | F4-03A | G/Y | No | 6u" |
B50S(28-07)G8-85-P223-B52 | 21.35*15.9*13.5 | Gigabit | G8-85 | G/Y | Yes | 6u" |
B50S(28-09)G8-96-P023-B52 | 21.35*15.9*13.5 | Gigabit | G8-96 | None | Yes | 6u" |
B50S(28-16)G8-09-P623-B52 | 21.35*15.9*13.5 | Gigabit | G8-09 | GO/Y | Yes | 6u" |
B50S(28-20)G8-96-P323-B52 | 21.35*15.9*13.5 | Gigabit | G8-96 | G/G | Yes | 6u" |
B50S(28-21)G12-95-P626-B52 | 21.35*15.9*13.5 | Gigabit | G12-95 | GY/G | Yes | 50u" |
B50S(28-27)G8-140-P623-B52 | 21.35*15.9*13.5 | Gigabit | G8-140 | GO/Y | Yes | 6u" |
B50S(28-29)G12-95-P223-B52 | 21.35*15.9*13.5 | Gigabit | G12-95 | G/Y | Yes | 6u" |
B50S(28-31)G8-164-P223-B52 | 21.35*15.9*13.5 | Gigabit | G8-164 | G/Y | Yes | 6u" |
B50S(28-39)G8-174-P623-B52 | 21.35*15.9*13.5 | Gigabit | G8-174 | G/GY | Yes | 6u" |
B50S(28-40)PF6-258A-P223-B52 | 21.35*15.9*13.5 | 100M | PF6-258A | G/Y | Yes | 6u" |
B50S(28-42)G8-98-P223-B52 | 21.35*15.9*13.5 | Gigabit | G8-98 | G/Y | Yes | 6u" |
B50S(28-43)G8-09-P223-B52 | 21.35*15.9*13.5 | Gigabit | G8-09 | G/Y | Yes | 6u" |
B50S(28-45)G8-107-P123-B52 | 21.35*15.9*13.5 | Gigabit | G8-107 | Y/G | Yes | 6u" |
B50S(28-48)G8-208-P623-B52 | 21.35*15.9*13.5 | Gigabit | G8-208 | GO/Y | Yes | 6u" |
B50(29-01)F4-100-P213-B52 | 25.4*16.2*13.5 | 100M | F4-100 | G/Y | No | 6u" |
B50(29-02)F5-190-P213-B52 | 25.4*16.2*13.5 | 100M | F5-190 | G/Y | No | 6u" |
B50(29-03)F4-24-P213-B52 | 25.4*16.2*13.5 | 100M | F4-24 | G/Y | No | 6u" |
B50(29-06)FP4-198-P613-B52 | 25.4*16.2*13.5 | 100M | FP4-198 | GO/Y | No | 6u" |
B50(29-07)F4-24-P222-B12 | 25.4*16.2*13.5 | 100M | F4-24 | G/Y | Yes | 6u" |
B50(29-15)F4-100C-P214-B52 | 25.4*16.2*13.5 | 100M | F4-100C | G/Y | No | 15u" |
B50(29-18)F4-03B-P613-B52 | 25.4*16.2*13.5 | 100M | F4-03B | GR/GR | No | 6u" |
B50(29-30)F4-17-P223-B52 | 25.4*16.2*13.5 | 100M | F4-17 | G/Y | Yes | 6u" |
B50(29-33)F5-190-P213-B52 | 25.4*16.2*13.5 | 100M | F5-190 | G/Y | No | 6u" |
B50(29-31)F4-240-P223-B52 | 25.4*16.2*13.5 | 100M | F4-240 | G/Y | Yes | 6u" |
B50(29-35)F5-83-P213-B52 | 25.4*16.2*13.5 | 100M | F5-83 | G/Y | No | 6u" |
B50(29-36)F4-24A-P223-B92 | 25.4*16.2*13.5 | 100M | F4-24A | G/Y | Yes | 6u" |
B50(29-53)F4-263-P223-B52 | 25.4*16.2*13.5 | 100M | F4-263 | G/Y | Yes | 6u" |
B50(29-59)F4-100-P613-B92 | 25.4*16.2*13.5 | 100M | F4-100 | G/GY | No | 6u" |
B50(29-60)F4-24-P113-B52 | 25.4*16.2*13.5 | 100M | F4-24 | Y/G | No | 6u" |
B50(30-08)F4-262-P003-C52 | 25.4*16.2*13.5 | 100M | F4-262 | None | No | 6u" |
B50(31-02)F4-42A-P003-B52 | 25.4*16.2*13.5 | 100M | F4-42A | None | No | 6u" |
B50(36-06)F5-190-P013-B52 | 25.4*16.2*13.5 | 100M | F5-190 | None | No | 6u" |
B50(02-02)G8-87-P213-B52 | 25.4*16.2*13.5 | Gigabit | G8-87 | G/Y | No | 6u" |
B50(02-05)G8-27-P212-B52 | 25.4*16.2*13.5 | Gigabit | G8-27 | G/Y | No | 6u" |
B50(02-06)G8-86-P613-B52 | 25.4*16.2*13.5 | Gigabit | G8-86 | G/GO | No | 6u" |
B50(02-09)G8-86-P613-B52 | 25.4*16.2*13.5 | Gigabit | G8-86 | GO/Y | No | 6u" |
B50(02-10)G8-91-P613-B52 | 25.4*16.2*13.5 | Gigabit | G8-91 | GO/Y | No | 6u" |
B50(02-13)G8-09-P213-B52 | 25.4*16.2*13.5 | Gigabit | G8-09 | G/Y | No | 6u" |
B50(02-19)G8-91-P123-B52 | 25.4*16.2*13.5 | Gigabit | G8-91 | Y/G | Yes | 6u" |
B50(02-22)G8-91-P614-B52 | 25.4*16.2*13.5 | Gigabit | G8-91 | GO/Y | No | 15u" |
B50(02-23)G8-120-P223-B12 | 25.4*16.2*13.5 | Gigabit | G8-120 | G/Y | Yes | 6u" |
B50(02-26)G8-140-P623-B52 | 25.4*16.2*13.5 | Gigabit | G8-140 | GO/Y | Yes | 6u" |
B50(02-28)G8-140-P023-B52 | 25.4*16.2*13.5 | Gigabit | G8-140 | None | Yes | 6u" |
B50(02-29)G8-98-P223-B52 | 25.4*16.2*13.5 | Gigabit | G8-98 | G/Y | Yes | 6u" |
B50(02-30)G8-140-P623-B52 | 25.4*16.2*13.5 | Gigabit | G8-140 | GO/Y | Yes | 6u" |
B50(02-33)G8-197-P613-B92 | 25.4*16.2*13.5 | Gigabit | G8-197 | G | No | 6u" |
B50(02-36)G8-91-P623-B52 | 25.4*16.2*13.5 | Gigabit | G8-91 | GO/Y | Yes | 6u" |
B50(150-07)GP8-15-P622-F52 | 32.6*16.6*13.5 | Gigabit | GP8-15 | GO/Y | Yes | 6u" |
B50(150-22)G8-12-P322-F52 | 32.6*16.6*13.5 | Gigabit | G8-12 | G/G | Yes | 6u" |
B50(150-53)GP12-106-P623-F12 | 32.6*16.6*13.5 | Gigabit | GP12-106 | GO/Y | Yes | 6u" |
B50(150-57)G8-13-P623-F52 | 32.6*16.6*13.5 | Gigabit | G8-13 | GY/G | Yes | 6u" |
B50(150-58)GP8-15-P623-F12 | 32.6*16.6*13.5 | Gigabit | GP8-15 | GY/G | Yes | 6u" |
B50(150-60)G8-12-P623-F12 | 32.6*16.6*13.5 | Gigabit | G8-12 | GY/G | Yes | 6u" |
B50(150-68)GP8-15C-P023-F52 | 32.6*16.6*13.5 | Gigabit | GP8-15C | None | Yes | 6u" |
B50(150-72)G8-13-P323-F52 | 32.6*16.6*13.5 | Gigabit | G8-13 | G/G | Yes | 6u" |
B50(150-73)G8-12-P623-F52 | 32.6*16.6*13.5 | Gigabit | G8-12 | GO/Y | Yes | 6u" |
B50(150-85)GP8-15A-P113-F52 | 32.6*16.6*13.5 | Gigabit | GP8-15A | Y/G | No | 6u" |
B50(150-88)GP8-15-P623-F52 | 32.6*16.6*13.5 | Gigabit | GP8-15 | GY/GY | Yes | 6u" |
B50(150-90)GP8-218-P023-B52 | 32.6*16.6*13.5 | Gigabit | GP8-218 | None | Yes | 6u" |
B50(151-01)F4-27-P622-F12 | 32.6*16.6*13.5 | 100M | F4-27 | GY/Y | Yes | 6u" |
B50(151-02)FP4-150-P622-F12 | 32.6*16.6*13.5 | 100M | FP4-150 | G/GO | Yes | 6u" |
B50(151-03)FP4-150-P623-F12 | 32.6*16.6*13.5 | 100M | FP4-150 | GO/GO | Yes | 6u" |
B50(151-06)F4-243-P223-F52 | 32.6*16.6*13.5 | 100M | F4-243 | G/Y | Yes | 6u" |
B50(152-02)F4-27-P023-F52 | 32.6*16.6*13.5 | 100M | F4-27 | None | Yes | 6u" |
Electrical | Mechanical | ||
---|---|---|---|
Current rating: | 1 - 1.5A | Insertion force: | 2 contacts---350g |
Voltage rating: | 120 - 150V AC | 4 contacts---500g | |
Insulation resistance: | 500MΩ Min | 6 contacts---750g | |
Withstand voltage: | AC 1500Vrms 50Hz or 60Hz 1 Min | 8 contacts---900g | |
Contact resistance: | 20mΩ Max | 10 contacts---1050g | |
PoE rating: | 15W, 350mA, 84V (For PoE product only) | Retention strength: | 7.7Kg between jack and plug |
Durability: | 750 mating cycles mini | ||
Material | |||
Housing: | 1) glass filled PA66(ul 94v-0) | ||
2) glass filled PA46(ul 94v-0) | |||
3) glass filled PBT(ul 94v-0) | |||
Spring wire: | 1) 0.45mm dia phosphor bronze gold plating over nickel | ||
2) 0.35mm thickness phosphor bronze alloy | |||
selective gold plating over nickel | |||
Shielding: | 0.2mm thickness copper alloy with tin plated | ||
Gold plating: | 3μ″,6μ″,15μ″,30μ″,50μ″ | ||
Working temperature: | -20℃-70℃, -40℃-85℃ | ||
Relative humidity: | 70%±10% RH |
Personne à contacter: cheng.yang
Gigabit industriel magnétique 1 de catégorie de LED RJ45 Jack 2x4 - 1.5A avec le transformateur
RJ45 magnétique à double accès Jack 1 - haute performance 1.5A avec la LED bicolore
Long corps RJ45 Jack avec le Magnetics, prise du connecteur RJ45 pour des applications de gigabit
Vert/jaune RJ45 a mené le connecteur, fonction empilée de PoE des connecteurs RJ45
Entrée minimum verticale de POE RJ45 Jack 350µH OCLTop pour le câble Ethernet rapide
RJ45 connecteur modulaire femelle, fonction 120 de POE de connecteur de LAN RJ45 - C.A. 150V
Verticale magnétique RJ45 Jack 10/100Mbps pour CAT 5 et câble Ethernet 6 rapide
10/100 base-T RJ45 vertical Jack le port simple 8mA de 180 degrés polarisent le courant SANS LED
Fonction Cat6 RJ45 Jack de PoE pour des networks interface cards et des applications de PC
RJ45 LAN vertical Jack, RJ45 norme simple du port IEEE802.3 pour meilleur UTP