Lieu d'origine: | La Chine |
Nom de marque: | B-TOP |
Numéro de modèle: | RJ45 magnétique Jack |
Quantité de commande min: | Négociable |
---|---|
Prix: | Negotiable |
Délai de livraison: | 10 jours de travail |
Conditions de paiement: | T/T |
Capacité d'approvisionnement: | 1000 PCS/Day |
Port: | 1*1 | LED: | Vert/vert |
---|---|---|---|
Plastique: | PBT | Taille: | 21.35*15.9*13.5 |
vitesse: | 100m | Estimation de tension :: | 120 - C.A. 150V |
Genre: | Femelle | Materia: | Bronze de phosphore, or plaqué |
Surligner: | RJ45 Magnetic Ethernet Jack,100M Magnetic Ethernet Jack,21.35*15.9*13.5 Magnetic RJ45 Jack |
Electronic Magnetic Ethernet Jack RJ 45 Female Dip Isolation Transformer
Electrical Performance :
* Meets or exceeds IEEE 802.3 standard for 100Base-T.
* 350 uH minimum OCL with 8 mA bias current.
* High performance for maximum EMI suppression.
* Minimum 1500 Vrms isolation per IEEE 802.3 requirement.
* Operating temperature range: 0 0C to +70 0C.
* Storage temperature range: -40 0C to +85 0C.
1.MATERIAL:
|
|
1-1.SHELL:
|
BRASS
|
1-2.HOUSING:
|
PBT+30%G.F. UL94 V-0 BLACK
|
1-3.TEMINARL:
|
Phosphor Bronze
|
2.PLATING SPECIFICATION
|
|
2-1.TERMINAL:
|
GOLD PLATED/3U"/6U"/15U"/30U"
|
2-2.SHELL:
|
NICKEL PLATED
|
3.MECHANICAL PERFORMANCE
|
|
3-1.INSERTION FORCE:
|
5N~20N.
|
3-2.WITHDRAWAL FORCE:
|
INITIAL 8N~20N , AFTER 1000 MATING CYCLES 6N~20N.
|
3-3.DURABILITY:
|
750 Cycles MIN.
|
4.ELECTRICAL PERFORMANCE
|
|
4-1.CURRENT RATING:
|
1.5A.
|
4-2.CONTACT RESISTANCE:
|
30milliohm Max
|
4-3.INSULATION RESISTANCE:
|
500 MΩ MIN @ 500V DC.
|
4-4.DIELECTRIC WITHSTAND VOLTAGE:
|
100V/AC.
|
5.OPERATING TEMPERATURE RANGE:
|
-40℃ to +85℃
|
6.RoHS COMPLIANT OR HALOGEN FREE COMPLIANT.
|
|
|
Part Number | Size | Speed | Schematic | LED | EMI Spring | Gold Plating |
BT50S(27-11)F4-03A-P213-B52 | 21.35*15.9*13.5 | 100M | F4-03A | G/Y | No | 6u" |
B50S(27-12)F4-239-P123-B52 | 21.35*15.9*13.5 | 100M | F4-239 | Y/G | Yes | 6u" |
B50S(27-16)F4-117-P223-B52 | 21.35*15.9*13.5 | 100M | F4-117 | G/Y | Yes | 6u" |
B50S(27-19)F4-03A-P223-B52 | 21.35*15.9*13.5 | 100M | F4-03A | G/Y | Yes | 6u" |
B50S(27-22)F4-03A-P213-B52 | 21.35*15.9*13.5 | 100M | F4-03A | G/Y | No | 6u" |
B50S(28-07)G8-85-P223-B52 | 21.35*15.9*13.5 | Gigabit | G8-85 | G/Y | Yes | 6u" |
B50S(28-09)G8-96-P023-B52 | 21.35*15.9*13.5 | Gigabit | G8-96 | None | Yes | 6u" |
B50S(28-16)G8-09-P623-B52 | 21.35*15.9*13.5 | Gigabit | G8-09 | GO/Y | Yes | 6u" |
B50S(28-20)G8-96-P323-B52 | 21.35*15.9*13.5 | Gigabit | G8-96 | G/G | Yes | 6u" |
B50S(28-21)G12-95-P626-B52 | 21.35*15.9*13.5 | Gigabit | G12-95 | GY/G | Yes | 50u" |
B50S(28-27)G8-140-P623-B52 | 21.35*15.9*13.5 | Gigabit | G8-140 | GO/Y | Yes | 6u" |
B50S(28-29)G12-95-P223-B52 | 21.35*15.9*13.5 | Gigabit | G12-95 | G/Y | Yes | 6u" |
B50S(28-31)G8-164-P223-B52 | 21.35*15.9*13.5 | Gigabit | G8-164 | G/Y | Yes | 6u" |
B50S(28-39)G8-174-P623-B52 | 21.35*15.9*13.5 | Gigabit | G8-174 | G/GY | Yes | 6u" |
B50S(28-40)PF6-258A-P223-B52 | 21.35*15.9*13.5 | 100M | PF6-258A | G/Y | Yes | 6u" |
B50S(28-42)G8-98-P223-B52 | 21.35*15.9*13.5 | Gigabit | G8-98 | G/Y | Yes | 6u" |
B50S(28-43)G8-09-P223-B52 | 21.35*15.9*13.5 | Gigabit | G8-09 | G/Y | Yes | 6u" |
B50S(28-45)G8-107-P123-B52 | 21.35*15.9*13.5 | Gigabit | G8-107 | Y/G | Yes | 6u" |
B50S(28-48)G8-208-P623-B52 | 21.35*15.9*13.5 | Gigabit | G8-208 | GO/Y | Yes | 6u" |
B50(29-01)F4-100-P213-B52 | 25.4*16.2*13.5 | 100M | F4-100 | G/Y | No | 6u" |
B50(29-02)F5-190-P213-B52 | 25.4*16.2*13.5 | 100M | F5-190 | G/Y | No | 6u" |
B50(29-03)F4-24-P213-B52 | 25.4*16.2*13.5 | 100M | F4-24 | G/Y | No | 6u" |
B50(29-06)FP4-198-P613-B52 | 25.4*16.2*13.5 | 100M | FP4-198 | GO/Y | No | 6u" |
B50(29-07)F4-24-P222-B12 | 25.4*16.2*13.5 | 100M | F4-24 | G/Y | Yes | 6u" |
B50(29-15)F4-100C-P214-B52 | 25.4*16.2*13.5 | 100M | F4-100C | G/Y | No | 15u" |
B50(29-18)F4-03B-P613-B52 | 25.4*16.2*13.5 | 100M | F4-03B | GR/GR | No | 6u" |
B50(29-30)F4-17-P223-B52 | 25.4*16.2*13.5 | 100M | F4-17 | G/Y | Yes | 6u" |
B50(29-33)F5-190-P213-B52 | 25.4*16.2*13.5 | 100M | F5-190 | G/Y | No | 6u" |
B50(29-31)F4-240-P223-B52 | 25.4*16.2*13.5 | 100M | F4-240 | G/Y | Yes | 6u" |
B50(29-35)F5-83-P213-B52 | 25.4*16.2*13.5 | 100M | F5-83 | G/Y | No | 6u" |
B50(29-36)F4-24A-P223-B92 | 25.4*16.2*13.5 | 100M | F4-24A | G/Y | Yes | 6u" |
B50(29-53)F4-263-P223-B52 | 25.4*16.2*13.5 | 100M | F4-263 | G/Y | Yes | 6u" |
B50(29-59)F4-100-P613-B92 | 25.4*16.2*13.5 | 100M | F4-100 | G/GY | No | 6u" |
B50(29-60)F4-24-P113-B52 | 25.4*16.2*13.5 | 100M | F4-24 | Y/G | No | 6u" |
B50(30-08)F4-262-P003-C52 | 25.4*16.2*13.5 | 100M | F4-262 | None | No | 6u" |
B50(31-02)F4-42A-P003-B52 | 25.4*16.2*13.5 | 100M | F4-42A | None | No | 6u" |
B50(36-06)F5-190-P013-B52 | 25.4*16.2*13.5 | 100M | F5-190 | None | No | 6u" |
B50(02-02)G8-87-P213-B52 | 25.4*16.2*13.5 | Gigabit | G8-87 | G/Y | No | 6u" |
B50(02-05)G8-27-P212-B52 | 25.4*16.2*13.5 | Gigabit | G8-27 | G/Y | No | 6u" |
B50(02-06)G8-86-P613-B52 | 25.4*16.2*13.5 | Gigabit | G8-86 | G/GO | No | 6u" |
B50(02-09)G8-86-P613-B52 | 25.4*16.2*13.5 | Gigabit | G8-86 | GO/Y | No | 6u" |
B50(02-10)G8-91-P613-B52 | 25.4*16.2*13.5 | Gigabit | G8-91 | GO/Y | No | 6u" |
B50(02-13)G8-09-P213-B52 | 25.4*16.2*13.5 | Gigabit | G8-09 | G/Y | No | 6u" |
B50(02-19)G8-91-P123-B52 | 25.4*16.2*13.5 | Gigabit | G8-91 | Y/G | Yes | 6u" |
B50(02-22)G8-91-P614-B52 | 25.4*16.2*13.5 | Gigabit | G8-91 | GO/Y | No | 15u" |
B50(02-23)G8-120-P223-B12 | 25.4*16.2*13.5 | Gigabit | G8-120 | G/Y | Yes | 6u" |
B50(02-26)G8-140-P623-B52 | 25.4*16.2*13.5 | Gigabit | G8-140 | GO/Y | Yes | 6u" |
B50(02-28)G8-140-P023-B52 | 25.4*16.2*13.5 | Gigabit | G8-140 | None | Yes | 6u" |
B50(02-29)G8-98-P223-B52 | 25.4*16.2*13.5 | Gigabit | G8-98 | G/Y | Yes | 6u" |
B50(02-30)G8-140-P623-B52 | 25.4*16.2*13.5 | Gigabit | G8-140 | GO/Y | Yes | 6u" |
B50(02-33)G8-197-P613-B92 | 25.4*16.2*13.5 | Gigabit | G8-197 | G | No | 6u" |
B50(02-36)G8-91-P623-B52 | 25.4*16.2*13.5 | Gigabit | G8-91 | GO/Y | Yes | 6u" |
B50(150-07)GP8-15-P622-F52 | 32.6*16.6*13.5 | Gigabit | GP8-15 | GO/Y | Yes | 6u" |
B50(150-22)G8-12-P322-F52 | 32.6*16.6*13.5 | Gigabit | G8-12 | G/G | Yes | 6u" |
B50(150-53)GP12-106-P623-F12 | 32.6*16.6*13.5 | Gigabit | GP12-106 | GO/Y | Yes | 6u" |
B50(150-57)G8-13-P623-F52 | 32.6*16.6*13.5 | Gigabit | G8-13 | GY/G | Yes | 6u" |
B50(150-58)GP8-15-P623-F12 | 32.6*16.6*13.5 | Gigabit | GP8-15 | GY/G | Yes | 6u" |
B50(150-60)G8-12-P623-F12 | 32.6*16.6*13.5 | Gigabit | G8-12 | GY/G | Yes | 6u" |
B50(150-68)GP8-15C-P023-F52 | 32.6*16.6*13.5 | Gigabit | GP8-15C | None | Yes | 6u" |
B50(150-72)G8-13-P323-F52 | 32.6*16.6*13.5 | Gigabit | G8-13 | G/G | Yes | 6u" |
B50(150-73)G8-12-P623-F52 | 32.6*16.6*13.5 | Gigabit | G8-12 | GO/Y | Yes | 6u" |
B50(150-85)GP8-15A-P113-F52 | 32.6*16.6*13.5 | Gigabit | GP8-15A | Y/G | No | 6u" |
B50(150-88)GP8-15-P623-F52 | 32.6*16.6*13.5 | Gigabit | GP8-15 | GY/GY | Yes | 6u" |
B50(150-90)GP8-218-P023-B52 | 32.6*16.6*13.5 | Gigabit | GP8-218 | None | Yes | 6u" |
B50(151-01)F4-27-P622-F12 | 32.6*16.6*13.5 | 100M | F4-27 | GY/Y | Yes | 6u" |
B50(151-02)FP4-150-P622-F12 | 32.6*16.6*13.5 | 100M | FP4-150 | G/GO | Yes | 6u" |
B50(151-03)FP4-150-P623-F12 | 32.6*16.6*13.5 | 100M | FP4-150 | GO/GO | Yes | 6u" |
B50(151-06)F4-243-P223-F52 | 32.6*16.6*13.5 | 100M | F4-243 | G/Y | Yes | 6u" |
B50(152-02)F4-27-P023-F52 | 32.6*16.6*13.5 | 100M | F4-27 | None | Yes | 6u" |
Electrical | Mechanical | ||
---|---|---|---|
Current rating: | 1 - 1.5A | Insertion force: | 2 contacts---350g |
Voltage rating: | 120 - 150V AC | 4 contacts---500g | |
Insulation resistance: | 500MΩ Min | 6 contacts---750g | |
Withstand voltage: | AC 1500Vrms 50Hz or 60Hz 1 Min | 8 contacts---900g | |
Contact resistance: | 20mΩ Max | 10 contacts---1050g | |
PoE rating: | 15W, 350mA, 84V (For PoE product only) | Retention strength: | 7.7Kg between jack and plug |
Durability: | 750 mating cycles mini | ||
Material | |||
Housing: | 1) glass filled PA66(ul 94v-0) | ||
2) glass filled PA46(ul 94v-0) | |||
3) glass filled PBT(ul 94v-0) | |||
Spring wire: | 1) 0.45mm dia phosphor bronze gold plating over nickel | ||
2) 0.35mm thickness phosphor bronze alloy | |||
selective gold plating over nickel | |||
Shielding: | 0.2mm thickness copper alloy with tin plated | ||
Gold plating: | 3μ″,6μ″,15μ″,30μ″,50μ″ | ||
Working temperature: | -20℃-70℃, -40℃-85℃ | ||
Relative humidity: | 70%±10% RH |
Insertion Loss dB max |
Return Loss dB min | Crosstalk(dB TYP) | Common Mode Rejection (dB TYP) |
Hipot(Vrms) | |||||
1-100MHz | 1-30MHz | 30-60MHz | 60-80MHz | 1-30MHz | 30-60MHz | 60-80MHz | 1-50MHz | 50-150MHz | |
-1.0 | -18 | -16 | -12 | -40 | -35 | -30 | -30 | -20 | 1500 |
Personne à contacter: cheng.yang
Gigabit industriel magnétique 1 de catégorie de LED RJ45 Jack 2x4 - 1.5A avec le transformateur
RJ45 magnétique à double accès Jack 1 - haute performance 1.5A avec la LED bicolore
Long corps RJ45 Jack avec le Magnetics, prise du connecteur RJ45 pour des applications de gigabit
Vert/jaune RJ45 a mené le connecteur, fonction empilée de PoE des connecteurs RJ45
Entrée minimum verticale de POE RJ45 Jack 350µH OCLTop pour le câble Ethernet rapide
RJ45 connecteur modulaire femelle, fonction 120 de POE de connecteur de LAN RJ45 - C.A. 150V
Verticale magnétique RJ45 Jack 10/100Mbps pour CAT 5 et câble Ethernet 6 rapide
10/100 base-T RJ45 vertical Jack le port simple 8mA de 180 degrés polarisent le courant SANS LED
Fonction Cat6 RJ45 Jack de PoE pour des networks interface cards et des applications de PC
RJ45 LAN vertical Jack, RJ45 norme simple du port IEEE802.3 pour meilleur UTP